Configuring Security using Device Manager 167Field DescriptionType This selection specifies the type of notification sentto a management target address. If the value is trap,sent messages contain SNMPv2-Trap PDUs. If thevalue is inform, messages contains Inform PDUs.ATTENTIONIf an SNMP entity only supports trap (and notinform) messages, this object can be read-only.StorageType Specifies whether this table entry (row) will be storedin volatile or nonvolatile memory. If the entry is storedin volatile memory, it does not persist if the switchloses power.2 Click Insert.The Notify Table, Insert dialog box appears .The following figure displays the Notify Table, Insert dialog box.Figure 54Notify Table, Insert dialog box3 Enter a Name for this table row.4 Enter a Tag name which connects this entry to one or more TargetAddress table entries.5 Specify the Type of message Protocol Data Units (PDUs) to send toan associated Management Target Address: trap or inform.6 Specify the StorageType.7 Click Insert.The new notify entry is shown in the list.Nortel Ethernet Routing Switch 2500 SeriesSecurity — Configuration and ManagementNN47215-505 (323165-B) 02.01 Standard4.1 19 November 2007Copyright © 2007, Nortel Networks.