Parameters ASDA-B2-F7-50 September, 20157P3-xx Communication ParametersP3-00● ADR Address Setting Address: 0300H0301HOperationalInterface: Panel / Software Communication RelatedSection: -Default: 01 ControlMode: ALLUnit: - Range: 0x01 ~ 0x7FFormat: HEX Data Size: 16-bitSettings:The communication address setting is divided into Y and X (hexadecimal):- 0 0 Y XRange - - 0 ~ 7 0 ~ FWhen using RS-232 to communicate, one servo drive can only set one address. Duplicate addresssetting will cause abnormal communication.This address represents the absolute address of the servo drive in the communication networkwhich is applicable to RS-232 and DMCNET bus.When the communication address setting of MODBUS is set to 0xFF, the servo drive willautomatically reply and receive data regardless of the address. However, P3-00 cannot be set to0xFF.P3-01 BRT Transmission Speed Address: 0302H0303HOperationalInterface: Panel / Software Communication RelatedSection: -Default: 3203 ControlMode: ALLUnit: Bps Range: 0x000 ~ 0x3405Format: HEX Data Size: 16-bitSettings:The setting of transmission speed is divided into Z, Y and X (hexadecimal):- 0 Z Y XCommunication Port - DMCNET - RS-232Range 0 0 ~ 4 0 0 ~ 5 Definition of setting value X0: 4800 1: 9600 2: 192003: 38400 4: 57600 5: 115200 Definition of setting value Z0: 125 Kbit/s 1: 250 Kbit/s 2: 500 Kbit/s3: 750 Kbit/s 4: 1.0 Mbit/s -Note:If this parameter is set via DMCNET, only Z can be set and the others remain.P3-02 PTL Communication Protocol Address: 0304H0305HOperationalInterface: Panel / Software Communication RelatedSection: -Default: 6 ControlMode: ALLUnit: Bps Range: 0 ~ 8Format: HEX Data Size: 16-bitSettings:The definition of the setting value is as the followings:0: 7, N, 2(MODBUS, ASCII) 1: 7, E, 1(MODBUS, ASCII) 2: 7, O, 1(MODBUS, ASCII)3: 8, N, 2(MODBUS, ASCII) 4: 8, E, 1(MODBUS, ASCII) 5: 8, O, 1(MODBUS, ASCII)