3 . I ns t r uc ti on Se t3- 4 0 3+3,000-3,000CurrentpositionRamp up timeStart / End freq. Min: 6HzRamp down time2. Registers for setting ramp up/down time and start/end frequency: Output Y0:Default: 100msY0(D1343)Y0(D1340) Y0 (D1340)Min: 6Hz Min: 6HzY0(D1343)Ramp-upslopeSample timeof ramp-up Pulse output frequencyEnd freq.Numbers ofoutput pulsesRamp down timeRamp up timeDefault: 100msCurrentpositionStart freq. This instruction can be used many times in user program, but only one instruction will beactivated at a time. For example, if Y0 is currently activated, other instructions use Y0 won’tbe executed. Therefore, instructions first activated will be first executed. After activating the instruction, all parameters cannot be modified unless instruction is OFF.3. Associated Flags:M1029: CH0 (Y0, Y1) pulse output execution completed.M1102: CH1 (Y2, Y3) pulse output execution completedM1078: CH0 (Y0, Y1) pulse output pause (immediate)M1104: CH1 (Y2, Y3) pulse output pause (immediate)M1108: CH0 (Y0, Y1) pulse output pause (ramp down).M1110: CH1 (Y2, Y3) pulse output pause (ramp down)M1156: Enabling the mask and alignment mark function on I400/I401(X4) correspondingto Y0.M1158: Enabling the mask and alignment mark function on I600/I601(X6) correspondingto Y2.