57Magtrol Model DSP7000 Dynamometer Controller C h a p t e r 5 – AlarmSystemSETUP • OPERATIONPOWERBRAKE STATUS SET POINT SET POINT P I DTORQUE SPEED USER DISPLAY**** ELECTRICAL ALARM TSCX ****TORQUE=XXX.XX XX RPM=X XXXXFigure 5–24 Electrical Alarm Message Display5.11.3 T o reSeT eleCTriCal alarMPress any front panel button other than ShIFT. The alarm condition must be cleared before the unitwill return to normal operation.5.12 ClutCh alarm (wb/pb only)In tandem setup, the clutch close signal will be sent. After 0.5 seconds, check the clutch closedsignal. If the clutch is open try resending the clutch close signal two more times. If the clutch isstill open go to the alarm.5.12.1 C luTCH alarM aCTionWhen there is a clutch failure, the display will flash “CLUTCh FAILURE” (as indicated in Figure5–25).POWERBRAKE STATUS SET POINT SET POINT P I DTORQUE SPEED USER DISPLAY**** CLUTCH FAILURE ****TORQUE=XXX.XX XX RPM=X XXXXFigure 5–25 Clutch Alarm Message Display5.12.2 T o reSeT CluTCH alarMPress any front panel button other than ShIFT. The alarm condition must be cleared before the unitwill return to normal operation.