– 106 –Chapter 4 Shooting — Setting the time data3 Set [TCG/TCR] in the main menu → [OUTPUT SEL] → [TC OUT].@@ NOTEt If you set [TC OUTPUT REF] to [VIDEO OUT] in the main menu → [OUTPUT SEL], the input time code will be output to match the video output delay.Connecting and setting the genlock and time code input/outputThe relationship of the connecting and settings between the genlock and time code input/output is shown in the table.When the genlock input and the camera output phase match, l is displayed, and when they do not match, × is displayed.r When the camera recording format is 1080P, 1080iCamera usage conditionsImage and standard signalssupplied externally SDI VIDEO SDI VIDEOGenlock input 1080i SD (480i/576i)Camera settings [GL PHASE] [HD SDI] [COMPOSITE] [HD SDI] [COMPOSITE]Genlock input and cameraoutput phaseSDI output (HD) l 90H advance l 90H advanceVideo output and SDI output(SD) 90H delay l 90H delay lTime code output l l l lr When the camera recording format is 1080/23.98PsFCamera usage conditions Image and standard signals supplied externally SDIGenlock input 1080/23.98PsFCamera settings [GL PHASE] [HD SDI]Genlock input and camera output phaseSDI output (HD) lVideo output and SDI output (SD) ×Time code output lr When the camera recording format is 720PCamera usage conditionsImage and standard signalssupplied externally SDI VIDEO SDI VIDEOGenlock input 720P SD (480i/576i)Camera settings [GL PHASE] [HD SDI] [COMPOSITE] [HD SDI] [COMPOSITE]Genlock input and cameraoutput phaseSDI output (HD) l 120H advance l 120H advanceVideo output and SDI output(SD) 120H delay l 120H delay lTime code output × × l lr When the camera recording format is 480i/576iCamera usage conditionsImage and standard signalssupplied externally SDI VIDEOGenlock input SD (480i/576i)Camera settings [GL PHASE] DisabledGenlock input and cameraoutput phaseSDI output (HD) NoneVideo output and SDI output(SD) lTime code output lSetting and displaying the counterIf you display the counter using the button, the counter value is displayed on the time code display of the viewfinder/LCD monitor. Countervalue is displayed as “hour:minute:second.frame”. The counter value is also displayed during playback.You can set either of two types in the main menu → [DISPLAY SETUP] → [REC COUNTER].[TOTAL]: The camera will continuously count until reset using the button. Even if you replace the P2 card or turn off the power, the value willbe maintained.[CLIP]: Each time you start recording the counter value will clear and the count will start from 0. You can shoot always while checking the recording timeof the clip you are currently shooting.@@ NOTEt If the button is pressed while the counter value is displayed, the counter value is reset. It will start again from 0.t The counter value is displayed by the frame unit.