PLC-HF10000L Expand Serial Command Functional Specifications100/1059.11 Other Status Read Commands9.11.1 CR_STATUS CommandCommand “CR_STATUS” [CR]Details Get operating status of ProjectorSame as “CR0” in basic command except error code follows it.Acceptable “000_%1” [CR]%1“00” = Power ON“80” = Standby“40” = Countdown in process“20” = Cooling Down in process“10” = Power Failure“28” = Cooling Down in process due to abnormal temperature“88” =Standby after Cooling Down due to abnormal temperature“24” = Power Save/Cooling Down in process“21” = Cooling Down in process after turned Off due to lampfailure“81” Standby after Cooling Down due to lamp failure“2C” = Cooling Down in process after Power Off due toShutter management“8C” = Standby after Cooling Down due to Shutter managementResponseUnacceptable “Error Code” [CR]9.11.2 CR_SIGNAL CommandCommand “CR_SIGNAL” [CR]Details Get status if there is any signal or notAcceptable “000_%1” [CR]%1 “ON” -------------------------- There is signal“OFF” ------------------------ There is no signalResponseUnacceptable “?” [CR]9.11.3 CR_VMUTE CommandCommand “CR_VMUTE” [CR]Details Get Video mute setting statusAcceptable “000_%1” [CR]%1 “ON” ------------------------ Video mute is set to ON (Shutter Close).“OFF” ---------------------- Video mute is set to OFF (Shutter Open).ResponseUnacceptable “?” [CR]9.11.4 CR_FREEZE CommandCommand “CR_FREEZE” [CR]Details Get Freeze setting statusAcceptable “000_%1” [CR]%1 “ON” ---------------------------- Freeze is set to ON.“OFF” -------------------------- Freeze is set to OFF.ResponseUnacceptable “?” [CR]