PLC-HF10000L Expand Serial Command Functional Specifications83/1059.9 Lamp Status Read Commands9.9.1 CR_LAMPREPL CommandCommand “CR_LAMPREPL” [CR]Details Get the information of Lamp Replacement timeAcceptable “000_%1” [CR]%1“2**”2 ---------------- indicates 2 lamps are used in this model.* ---------------- indicates the status of each lamp in lamp numberorder.“Y” means the lamp operating time is over thethreshold for lamp replacement, and “N” meansit has not reached to.e.g.“2YN” ------------ This indicates it is 2-lamp system, and Lamp #2has not been reached to the replacement timewhile #1 should be replaced.ResponseUnacceptable “?” [CR]9.9.2 CR_LAMPMODE CommandCommand “CR_LAMPMODE” [CR]Details Get Lamp mode setting statusAcceptable “000_%1” [CR]%1“2LAMP” ------------- Lamp mode is set to 2-Lamps“1LAMPAUTO” --- Lamp mode is set to 1-Lamp (Auto) andautomatically and preferentially uses a lampwith shorter cumulated lighting time“1LAMP1” ----------- Lamp mode is set to 1-Lamp (LAMP1)“1LAMP2” ----------- Lamp mode is set to 1-Lamp (LAMP2)“CONSTANT” ------ Lamp mode is set to Constant mode.ResponseUnacceptable “Error Code” [CR]9.9.3 CR_LAMPCONSTTAR CommandCommand “CR_LAMPCONSTTAR” [CR]Details Get value of Target for Constant modeAcceptable “000_%1” [CR]%1 “0000”-“1024”ResponseUnacceptable “Error Code” [CR]9.9.4 CR_LAMPCONSTCUR CommandCommand “CR_LAMPCONSTCUR” [CR]Details Get value of Current for Constant modeAcceptable “000_%1” [CR]%1 “0000”-“1024”ResponseUnacceptable “Error Code” [CR]