PLC-HF10000L Expand Serial Command Functional Specifications88/1059.10.10 CR_P-MANE CommandCommand “CR_P-MANE” [CR]Details Get setting status of Power managementAcceptable “000_%1” [CR]%1“OFF” ------------------------ Power Management is disabled“READY” -------------------- Power Management is set to Ready“SHUTDOWN” -----Power Management is set to Shut Down modeResponseUnacceptable “?” [CR]9.10.11 CR_P-MANETIME CommandCommand “CR_P-MAETIME” [CR]Details Get setting time for starting Power Management functionAcceptable “000_%1” [CR]%1 “001 – 030” ----------------------- 1 to 30 minutesResponseUnacceptable “?” [CR]9.10.12 CR_ON-STA CommandCommand “CR_ON-STA” [CR]Details Get Direct on setting statusAcceptable “000_%1” [CR]%1 “ON” -------------------------- Direct on is set to ON.“OFF” ------------------------ Direct on is set to OFF.ResponseUnacceptable “?” [CR]9.10.13 CR_SECURITY CommandCommand “CR_ SECURITY” [CR]Details Get ON/OFF setting status of Security on menu.Acceptable “000_%1” [CR]%1 “ON” ------------ PJ is locked“OFF” ----------- PJ is not locked.ResponseUnacceptable “Error Code” [CR]9.10.14 CR_PJLOCKNOW CommandCommand “CR_PJLOCKNOW” [CR]Details Get actual setting status of PIN code lockAcceptable “000_%1” [CR]%1“LOCK” ------ PJ is lockedPIN code lock is set to ON1/ON2 on the menu and PJ PINcode is not entered, therefore PJ is actually locked.“FREE” ------- PJ is unlocked (either A or B)A) PJ lock is set to OFF on the menuB) PJ lock is set to ON1/ON2 on the menu, but PIN code Lockmode is canceled because PJ PIN code is entered.ResponseUnacceptable “Error Code” [CR]