PLC-HF10000L Expand Serial Command Functional Specifications85/1059.9.10 CR_LAMPH CommandCommand “CR_LAMPH” [CR]Details Get Lamp running time (in hours)* return actual lamp running timeAcceptable “000_%1_%2_%3_%4” [CR]%1_%2%3_%4Lamp 1 data comes first, and then one space, after that lamp 2data is followed.%1 = lamp No.1%2 = lamp No.2%3 = lamp No.3%4 = lamp No.4In the case of 2-lamps model, % 1 and % 2 are only usedThere are no % 3 and % 4e.g.; “00410_00410_00410_00410” [CR]▪▪▪▪ → Lamp No.1 = 410 HoursLamp No.2 = 410 HoursLamp No.3 = 410 HoursLamp No.4 = 410 HoursResponseUnacceptable “Error Code” [CR]9.9.11 CR_LAMPCORRESPH CommandCommand “CR_LAMPCORRESPH” [CR]Details Get Lamp running time (in hours)*return lamp running time multiplied by a coefficient (not actual running time)Acceptable “000_%1” [CR]%1 “00000”-“99999”ResponseUnacceptable “Error Code” [CR]9.9.12 CR_LAMPINTERVAL CommandCommand “CR_LAMPINTERVAL” [CR]Details Get setting status of Lamp intervalAcceptable “000_%1” [CR]%1“0024”------------------ 24 Hours is selected“0200”------------------ 200 Hours is selected“0500”------------------ 500 Hours is selected“1000”------------------ 1000 Hours is selected“2000”------------------ 2000 Hours is selected“OFF” ------------------ Off is selectedResponseUnacceptable “?” [CR]9.9.13 CR_LAMPLIFECONTRL CommandCommand “CR_LAMPLIFECONTRL” [CR]Details Get setting status of Lamp life control.(Available only in the normal Power ON status)Acceptable “000_%1” [CR]%1 “MODE1” ---------------- Mode1 is selected“MODE2”----------------- Mode2 is selectedResponseUnacceptable “Error Code” [CR]