PLC-HF10000L Expand Serial Command Functional Specifications58/1058.9.52 CF_PTIME CommandCommand “CF_PTIME_%1” [CR]%1 “001” – “180” -------------------------- Directly specify setting timeDetailsSet the time for Count down mode of P-timer.(Available only in the normal Power ON status)The status set by this command is stored in EEPROM and setting value remainseffective even after the power is turned to ALL OFF status.Acceptable “000” [CR]ResponseUnacceptable “Error Code” [CR]8.9.53 CF_FILCTL CommandCommand “CF_FILCTL_%1” [CR]%1 “ROLL” ---------------------- Execute operation of scroll of filterDetails Execute operation of scroll of filterAcceptable “000” [CR]ResponseUnacceptable “Error Code” [CR]8.9.54 CF_FILSCRL CommandCommand “CF_FILSCRL_%1” [CR]%1 “RST” ---------------------- Reset Filter scroll counterDetails Reset Filter scroll counterAcceptable “000” [CR]ResponseUnacceptable “Error Code” [CR]8.9.55 CF_TESTPAT CommandCommand “CF_TESTPAT_%1” [CR]%1“COLOR” ---------------------- Display Color bar“GRAD1” ---------------------- Display 16step(white→black)“GRAD2” ---------------------- Display 16step(white←black)“GRAD3” ---------------------- Display 16step(white↓black)“GRAD4” ---------------------- Display 16step(white↑black)“WHITE” ---------------------- Display all white“BLACK” ---------------------- Display all black“CROSS” --------------------- Display Cross“OFF” ---------------------------Do not show test pattern displayDetails Execute test pattern display.(Available only in the normal Power ON status)Acceptable “000” [CR]ResponseUnacceptable “Error Code” [CR]8.9.56 CF_FDEFAULT CommandCommand “CF_FDEFAULT_%1” [CR]%1 “RST”Details Return the settings to Factory Default status (Valid only when in the normal PowerON status)Acceptable “000” [CR]ResponseUnacceptable “Error Code” [CR]