PLC-HF10000L Expand Serial Command Functional Specifications38/1058.7.10 CF_CEIL CommandCommand “CF_CEIL_%1” [CR]%1 “ON” --------------------------- Set Ceiling to ON“OFF” ------------------------- Set Ceiling to OFFDetailsSet/Cancel Ceiling. (Valid only when in the normal Power ON status.)When Ceiling is set to ON, image is left/right as well as top/bottom reversed.The status set by this command is stored in EEPROM and the setting remainseffective after the power is turned to ALL OFF status.Acceptable “000” [CR]ResponseUnacceptable “Error Code” [CR]8.7.11 CF_REAR CommandCommand “CF_REAR_%1” [CR]%1 “ON” --------------------------- Set Rear to ON“OFF” ------------------------- Set Rear to OFFDetailsSet/Cancel Rear. (Valid only when in the normal Power ON status.)When Rear is set to ON, image is left/right reversed.The status set by this command is stored in EEPROM and the setting remainseffective after the power is turned to ALL OFF status.Acceptable “000” [CR]ResponseUnacceptable “Error Code” [CR]8.7.12 CF_VSCALE CommandCommand “CF_VSCALE_%1” [CR]%1“035” ---------------------- +35“031” ---------------------- +31“001” ---------------------- +1“000” ---------------------- ±0“ 01” --------------------- 1“ 31” --------------------- 31“ 32” --------------------- 32“UP” --------------------- Increment setting value of Vscale by 1“DN” --------------------- Decrement setting value of Vscale by 1DetailsSet Vscale (Available only in the normal Power ON status)*When selected screen mode is a setting except Custom, return “101” [CR] andthe command is not executed.* When input is no signal, return “101” [CR] and the command is not executed.Acceptable “000” [CR]ResponseUnacceptable “Error Code” [CR]