PLC-HF10000L Expand Serial Command Functional Specifications39/1058.7.13 CF_VPOS CommandCommand “CF_VPOS_%1” [CR]%1“015” --------------------- +15“014” --------------------- +14“001” --------------------- +1“000” --------------------- ±0“ 01” --------------------- 1“ 14” --------------------- 14“ 15” --------------------- 15“UP” --------------------- Increment setting value of Vposition by 1“DN” --------------------- Decrement setting value of Vposition by 1DetailsSet V Position (Available only in the normal Power ON status)*When selected screen mode is a setting except Custom, return “101” [CR] andthe command is not executed.* When input is no signal, return “101” [CR] and the command is not executed.Acceptable “000” [CR]ResponseUnacceptable “Error Code” [CR]8.7.14 CF_HSCALE CommandCommand “CF_HSCALE_%1” [CR]%1“035” ---------------------- +35“031” ---------------------- +31“002” ---------------------- +2“001” ---------------------- +1“000” ---------------------- ±0“ 01” --------------------- 1“ 02” --------------------- 2“ 31” --------------------- 31“ 32” --------------------- 32“UP” --------------------- Increment setting value of Hscale by 1“DN” --------------------- Decrement setting value of Hscale by 1DetailsSet Hscale (Available only in the normal Power ON status)*When selected screen mode is a setting except Custom, return “101” [CR] andthe command is not executed.* When input is no signal, return “101” [CR] and the command is not executed.Acceptable “000” [CR]ResponseUnacceptable “Error Code” [CR]