PLC-HF10000L Expand Serial Command Functional Specifications69/1059.5 PC Status Read Commands9.5.1 CR_FSYNC CommandCommand “CR_FSYNC” [CR]Details Get value of Fine SyncAcceptable “000_%1” [CR]Response%1 “0000” – “0031”Unacceptable“Error Code” [CR] -------------- When command is invalid in thegiven condition (such as being selected input)“?” [CR] --------- When unknown command is received9.5.2 CR_TDOTS CommandCommand “CR_TDOTS” [CR]Details Get value of Total DotsAcceptable “000_%1” [CR]%1“mmmm” – “nnnn”(mmmm = Display area H + Position H)(nnnn = Maximum value less than 160 MHz of Dot Clock)ResponseUnacceptable“Error Code” [CR] -------------- When command is invalid in thegiven condition (such as being selected input)“?” [CR] --------- When unknown command is received9.5.3 CR_H-POS CommandCommand “CR_H-POS” [CR]Details Get value of Horizontal PositionAcceptable “000_%1” [CR]%1 “0000” – “ nnnn”(nnnn = Total Dots - Display Area H)ResponseUnacceptable“Error Code” [CR] -------------- When command is invalid in thegiven condition (such as being selected input)“?” [CR] --------- When unknown command is received9.5.4 CR_V-POS CommandCommand “CR_V-POS” [CR]Details Get value of Vertical PositionAcceptable “000_%1” [CR]%1 “0000” – “ nnnn”(nnnn = Total Line - Display Area V)ResponseUnacceptable“Error Code” [CR] -------------- When command is invalid in thegiven condition (such as being selected input)“?” [CR] --------- When unknown command is received