PLC-HF10000L Expand Serial Command Functional Specifications63/1058.10.3 CF_POWER CommandCommand “CF_POWER_%1” [CR]%1“ON” ----------------------------- Power ON“OFF” --------------------------- Power OFF* Issuing another command during countdown process forced countdownoperation to be terminated.* Error Code is returned in some projector statuses, which indicates the commandis impossible to be executed. (See [8.3] for details)* Returning the response “000” [CR] (acceptable) does not always mean that thestatus has already changed to Power ON.Ex: When the temperature approaches abnormal status after returning “000” [CR]to the command CF_POWER ON.Therefore, to get the projector status requires using Status Read command.Details Set Power to ON/OFFAcceptable “000” [CR]ResponseUnacceptable “Error Code” [CR]8.10.4 CF_FREEZE CommandCommand “CF_FREEZE_%1” [CR]%1“ON” --------------------------- Set Freeze to ON.“OFF” ------------------------- Set Freeze to OFF.“UP” ----------- The same operation as pressing Up key or Left key“DN” -----------The same operation as pressing Down key or Right key* The same operation for “UP” and “DN” as this model has only “ON” / “OFF”.DetailsSet / Cancel Freeze function. (Available only in the normal Power ON status)Receiving FREEZE_ON command when the projector is Freeze enabled, Freezestatus is kept.Acceptable “000” [CR]ResponseUnacceptable “Error Code” [CR]8.10.5 CF_VMUTE CommandCommand “CF_VMUTE_%1” [CR]%1 “ON” --------------------------- Set Video Mute to ON (Shutter Close).“OFF” ------------------------- Set Video Mute to OFF (Shutter Open).Details ON / OFF Video Mute function. (Available only in the normal Power ON status)Acceptable “000” [CR]ResponseUnacceptable “Error Code” [CR]