PLC-HF10000L Expand Serial Command Functional Specifications87/1059.10.5 CR_LOGO CommandCommand “CR_LOGO” [CR]Details Get Logo setting statusAcceptable “000_%1” [CR]%1“DFLT” ----------------------------- Default Logo is enabled“USER” --------------------------- User is enabled“OFF” ------------------------------ Off is enabledResponseUnacceptable “?” [CR]9.10.6 CR_LOGOLOCK CommandCommand “CR_LOGOLOCK” [CR]Details Get setting status of Logo Lock functionAcceptable “000_%1” [CR]%1 “ON” --------------------------- Logo Lock is ON“OFF” ------------------------- Logo Lock is OFFResponseUnacceptable “Error Code” [CR]9.10.7 CR_FANSPEED CommandCommand “CR_FANSPEED” [CR]Details Get currently selected Fan Control SpeedAcceptable “000_%1” [CR]%1 “MAX” -------------------- Max speed of Fan Control is selected“NOR” -------------------- Normal speed of Fan Control is selectedResponseUnacceptable “?” [CR]9.10.8 CR_RCODE CommandCommand “CR_RCODE” [CR]Details Get currently selected Remote Control codeAcceptable “000_%1” [CR]%1“001” -------------------------- Code1“002” -------------------------- Code2:“007” -------------------------- Code7“008” -------------------------- Code8ResponseUnacceptable “?” [CR]9.10.9 CR_RSENS CommandCommand “CR_RSENS” [CR]Details Get selected location of infrared remote receiver of remote controlAcceptable “000_%1” [CR]%1“BOTH” --------Select both front and back receiver of projector“FRONT” ----- Select only front receiver of projector“BACK” ------- Select only back receiver of projectorResponseUnacceptable “?” [CR]