5.4 Operator Programming Errorsu Operator Programming Error Codes, Causes, and Possible SolutionsAn Operator Programming Error (oPE) occurs when a contradictory parameter is set or an individual parameter is set to aninappropriate value.The drive will not operate until the parameter or parameters causing the problem are set correctly. An oPE, however, does nottrigger an alarm or fault output. If an oPE occurs, investigate the cause and refer to Table 5.4 for the appropriate action. WhenoPE02 or oPE08 appear on the operator display, press the ENTER button to view U1-18 and see which parameter is causingthe oPE.Table 5.4 oPE Codes, Causes, and Possible SolutionsoPE01 Drive Capacity Setting FaultDrive capacity and the value set to o2-04 do not match.oPE02 Parameter Range Setting ErrorUse U1-18 to find parameters set outside the range.oPE03Multi-Function Input Selection ErrorA contradictory setting is assigned to multi-function contact inputs H1-01to H1-08.oPE04 Initialization RequiredoPE05 Run Command/Frequency Reference Source Selection ErroroPE06 Control Method Selection ErrorCorrect the setting for the control method.oPE07Multi-Function Analog Input Selection ErrorA contradictory setting is assigned to multi-function analog inputs H3-02,H3-10, or H3-06 and PID functions conflict.oPE08Parameter Selection ErrorA function has been set that cannot be used in the motor control methodselected.oPE09PID Control Selection FaultPID control function selection is incorrect. Requires that PID control isenabled (b5-01 = 1 to 4).oPE10V/f Data Setting ErrorOne or more of the parameters listed below are not set according to theformula:• E1-09 ≤ E1-07 < E1-06 ≤ E1-11 ≤ E1-04• E3-09 ≤ E3-07 < E3-06 ≤ E3-11 ≤ E3-04oPE11 Carrier Frequency Setting ErrorCorrect the setting for the carrier frequency.oPE13 Pulse Monitor Selection ErrorIncorrect setting of monitor selection for pulse train (H6-06).oPE15Torque Control Setting ErrorParameter settings that are not allowed in combination with Torque Controlhave been set.oPE16 Energy Savings Constants ErroroPE18 Online Tuning Parameter Setting ErrorParameters controlling online tuning are not set correctly.5.4 Operator Programming ErrorsYASKAWA ELECTRIC TOEP C710616 41G YASKAWA AC Drive - A1000 Quick Start Guide 2035 Troubleshooting