Contents - QUICK REFERENCE
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- YASKAWA ELECTRIC TOEP C710616 41G YASKAWA AC Drive - A1000 Quick Start Guide
- i.1 Preface
- i.2 General Safety
- Safety Messages
- General Application Precautions
- Motor Application Precautions
- Drive Label Warning Example
- RECEIVING
- Model Number and Nameplate Check
- MECHANICAL INSTALLATION
- Instructions on Installation Using the Eye Bolts
- Flange Type Enclosure (NEMA 12 Backside) Dimensions & Heat Loss
- Flange Type Models 2A0018 and 2A0021, 4A0007 to 4A0011, and 5A0006 and 5A0009
- Flange Type Models 2A0030 and 2A0040, 4A0018 and 4A0023, and 5A0011
- Flange Type Model 4A0031
- Flange Type Models 2A0056, 4A0038, and 5A0017 and 5A0022
- Flange Type Models 2A0069 and 2A0081, 4A0044, and 5A0027 and 5A0032
- Flange Type Models 2A0110 and 4A0058
- Flange Type Models 2A0138, 4A0072, and 5A0041 and 5A0052
- Flange Type Models 4A0088 and 4A0103
- Flange Type Models 2A0169 and 2A0211, 4A0139 and 4A0165, and 5A0062 to 5A0099
- Flange Type Models 2A0250 and 2A0312, 4A0208, and 5A0125 and 5A0145
- Flange Type Models 2A0360 and 2A0415, 4A0250 to 4A0362, and 5A0192 and 5A0242
- Flange Type Model 4A0414
- Flange Type Models 4A0515 and 4A0675
- Flange Type Models 4A0930 and 4A1200
- ELECTRICAL INSTALLATION
- Standard Connection Diagram
- Main Circuit Connection Diagram
- Three-Phase 400 V Class Models 4A0088 to 4A0139 Three-Phase 600 V Class Models 5A0062 to 5A0099
- Three-Phase 400 V Class Models 4A0930, 4A1200
- Terminal Cover
- Models 2A0110 to 2A0250, 4A0208 to 4A1200, and 5A0125 to 5A0242 (IP00/Open Type Enclosure)
- Digital Operator and Front Cover
- Top Protective Cover
- Main Circuit Wiring
- Protecting Main Circuit Terminals
- Main Circuit Terminal and Motor Wiring
- Control Circuit Wiring
- Terminal Configuration
- Wiring the Control Circuit Terminal
- Control I/O Connections
- Sinking/Sourcing Mode Selection for Safe Disable Inputs
- Using the Pulse Train Output
- Terminal A2 Input Signal Selection
- Terminal DM+ and DM- Output Signal Selection
- Wiring Checklist
- START-UP PROGRAMMING & OPERATION
- Using the Digital Operator
- LCD Display
- ALARM (ALM) LED Displays
- Menu Structure for Digital Operator
- The Drive and Programming Modes
- Switching Between LOCAL and REMOTE
- Start-Up Flowcharts
- Flowchart A: Basic Start-Up and Motor Tuning
- Subchart A-1: Simple Motor Setup Using V/f Control
- Subchart A-2: High Performance Operation Using OLV or CLV
- Subchart A-3: Operation with Permanent Magnet Motors
- Powering Up the Drive
- Application Selection
- Basic Drive Setup Adjustments
- Auto-Tuning
- Auto-Tuning Interruption and Fault Codes
- Auto-Tuning Operation Example
- No-Load Operation Test Run
- Test Run with Load Connected
- Test Run Checklist
- TROUBLESHOOTING
- Drive Alarms, Faults, and Errors
- Fault Detection
- Alarm Detection
- Operator Programming Errors
- Causes and Possible Solutions for a Blank and Unresponsive Digital Operator
- Auto-Tuning Fault Detection
- Copy Function Related Displays
- PERIODIC INSPECTION & MAINTENANCE
- Inspection
- Recommended Periodic Inspection
- Storage Guidelines
- Periodic Maintenance
- Drive Replacement
- PERIPHERAL DEVICES & OPTIONS
- Option Card Installation
- PG Option Installation Example
- A. SPECIFICATIONS
- A.1 Heavy Duty and Normal Duty Ratings
- A.2 Power Ratings
- Three-Phase 200 V Class Drive Models 2A0040 to 2A0211
- Three-Phase 200 V Class Drive Models 2A0250 to 2A0415
- Three-Phase 400 V Class Drive Models 4A0002 to 4A0031
- Three-Phase 400 V Class Drive Models 4A0038 to 4A0165
- Three-Phase 400 V Class Drive Models 4A0208 to 4A1200
- Three-Phase 600 V Class Drive Models 5A0003 to 5A0032
- Three-Phase 600 V Class Drive Models 5A0041 to 5A0099
- Three-Phase 600 V Class Drive Models 5A0125 to 5A0242
- A.3 Drive Specifications
- A.4 Drive Watt Loss Data
- B. PARAMETER LIST
- B.1 A: Initialization Parameters
- A2: User Parameters
- B.2 b: Application
- b2: DC Injection Braking and Short Circuit Braking
- b4: Timer Function
- b5: PID Control
- b6: Dwell Function
- b9: Zero Servo
- B.3 C: Tuning
- C2: S-Curve Characteristics
- C4: Torque Compensation
- C6: Carrier Frequency
- B.4 d: References
- d2: Frequency Upper/Lower Limits
- d3: Jump Frequency
- d5: Torque Control
- d7: Offset Frequency
- B.5 E: Motor Parameters
- E2: Motor 1 Parameters
- E3: V/f Pattern for Motor 2
- E4: Motor 2 Parameters
- E5: PM Motor Settings
- B.6 F: Option Settings
- F2: Analog Input Card Settings (AI-A3)
- F4: Analog Monitor Card Settings (AO-A3)
- F6: Communication Option Card Settings (SI-B3, SI-C3, SI-ES3, SI-ET3, SI-N3, SI-P3, SI-S3, SI T3, SI-W3)
- F7: Communication Option Card Settings (SI-EM3, SI-EN3, SI-EP3)
- B.7 H Parameters: Multi-Function Terminals
- H2: Multi-Function Digital Outputs
- H3: Multi-Function Analog Inputs
- H4: Analog Outputs
- H5: MEMOBUS/Modbus Serial Communication
- H6: Pulse Train Input/Output
- B.8 L: Protection Function
- L2: Momentary Power Loss Ride-Thru
- L3: Stall Prevention
- L4: Speed Detection
- L5: Fault Restart
- L7: Torque Limit
- L8: Drive Protection
- L9: Drive Protection 2
- B.9 n: Special Adjustment
- n5: Feed Forward Control
- B.10 o: Operator-Related Settings
- o3: Copy Function
- B.11 DriveWorksEZ Parameters
- B.12 T: Motor Tuning
- T2: PM Motor Auto-Tuning
- T3: ASR and Inertia Tuning
- B.13 U: Monitors
- U2: Fault Trace
- U3: Fault History
- U4: Maintenance Monitors
- U5: PID Monitors
- U8: DriveWorksEZ Monitors
- C. STANDARDS COMPLIANCE
- C.1 European Standards
- EMC Guidelines Compliance
- C.2 UL and CSA Standards
- CSA Standards Compliance
- Precautionary Notes on External Heatsink (IP00/Open Type Enclosure)
- C.3 Safe Disable Input Function
|
Drive ModelHeavy DutyNominalOutput PowerHPAC Drive InputAmpsMCCB RatingAmps<1>Time Delay FuseRating Amps <2>Non-time DelayFuse RatingAmps <3>Bussmann Semi-conductor FuseRating (FuseAmpere) <4>4A0004 1 - 2 3.2 15 5 9 FWH-50B (50)4A0005 3 4.4 15 7 12 FWH-70B (70)4A0007 3 6 15 10 17.5 FWH-70B (70)4A0009 5 8.2 15 12 20 FWH-90B (90)4A0011 5 10.4 20 17.5 30 FWH-90B (90)4A0018 7.5 - 10 15 30 25 40 FWH-80B (80)4A0023 10 20 40 35 60 FWH-100B (100)4A0031 15 29 50 50 80 FWH-125B (125)4A0038 20 39 75 60 110 FWH-200B (200)4A0044 25 - 30 47 75 75 125 FWH-250A (250)4A0058 30 43 75 75 125 FWH-250A (250)4A0072 40 58 100 100 150 FWH-250A (250)4A0088 60 71 125 110 200 FWH-250A (250)4A0103 60 86 150 150 250 FWH-250A (250)4A0139 75 105 175 175 300 FWH-350A (350)4A0165 100 142 225 225 400 FWH-400A (400)4A0208 125 - 150 170 250 250 500 FWH-500A (500)4A0250 150 207 350 350 600 FWH-600A (600)4A0296 200 248 400 400 700 FWH-700A (700)4A0362 250 300 500 500 800 FWH-800A (800)4A0414 300 346 600 600 1000 <4> FWH-800A (800)4A0515 350 410 700 700 1200 <4> FWH-1000A (1000)4A0675 400 - 500 584 1000 1000 <4> 1600 <4> FWH-1200A (1200)4A0930 600 - 700 830 Not Applicable FWH-1200A (1200)4A1200 800 - 900 1031 FWH-1600A (1600)600 V Class5A0003 1 1.9 15 3 5 FWP-50B (50)5A0004 2 3.6 15 6.25 10 FWP-50B (50)5A0006 3 5.1 15 8 15 FWP-60B (60)5A0009 5 8.3 15 12 20 FWP-60B (60)5A0011 7.5 12 20 20 35 FWP-70B (70)5A0017 10 16 30 25 45 FWP-100B (100)5A0022 15 23 40 40 60 FWP-100B (100)5A0027 20 31 60 50 90 FWP-125A (125)5A0032 25 38 75 60 100 FWP-125A (125)5A0041 30 33 60 50 90 FWP-175A (175)5A0052 40 44 75 75 125 FWP-175A (175)5A0062 50 54 100 90 150 FWP-250A (250)5A0077 60 66 125 110 175 FWP-250A (250)5A0099 75 80 150 125 225 FWP-250A (250)5A0125 100 108 175 175 300 FWP-350A (350)5A0145 125 129 250 225 350 FWP-350A (350)5A0192 150 158 300 250 400 FWP-600A (600)5A0242 200 228 400 350 600 FWP-600A (600)<1> Maximum MCCB Rating is 15 A, or 200 % of drive input current rating, whichever is larger. MCCB voltage rating must be 600 VAC or greater.<2> Maximum Time Delay fuse is 175% of drive input current rating. This covers any Class CC, J or T class fuse.<3> Maximum Non-time Delay fuse is 300% of drive input current rating. This covers any CC, J or T class fuse.C.2 UL and CSA StandardsYASKAWA ELECTRIC TOEP C710616 41G YASKAWA AC Drive - A1000 Quick Start Guide 347C Standards Compliance PreviousNext |