B.6 F: Option SettingsF parameters program the drive for PG feedback from the motor and to function with option cards.u F1: PG Speed Control Card (PG-B3, PG-X3, PG-RT3, PG-F3)Parameters F1-01, F1-05, F1-06, F1-12, F1-13, and F1-18 through F1-21 include “PG 1” in the parameter name and are usedto set up a PG option card plugged into option port CN5-C of the drive.Parameters F1-31 through F1-37 include “PG 2” in the parameter name and are used to set up a PG option card plugged intooption port CN5-B of the drive.Other parameters in the F1 group are used to set operation for PG options plugged into port CN5-C and CN5-B.No.(Addr.Hex) Name LCD Display Description Values PageF1-01(0380) PG 1 Pulses PerRevolution PG1 Pulses/RevSets the number of PG (pulse generator or encoder) pulses. Setsthe number of pulses per motor revolution.Note: Setting range is 0 to 15000 ppr when A1-02 = 7(CLV/PM control mode).Default: 1024 pprMin.: 1Max.: 60000 –F1-02(0381) Operation Selection atPG Open Circuit (PGo)PG Fdbk Loss Sel0: Ramp to Stop1: Coast to Stop2: Fast-Stop3: Alarm Only4: Not Detect0: Ramp to stop. Decelerate to stop using the deceleration timein C1-02.1: Coast to stop.2: Fast Stop. Decelerate to stop using the deceleration time inC1-09.3: Alarm only.4: No alarm displayNote: Depending on motor speed and load conditions,an error such as ov or oC may occur.Default: 1Range: 0 to 4 –F1-03(0382) Operation Selection atOverspeed (oS)PG Overspeed Sel0: Ramp to Stop1: Coast to Stop2: Fast-Stop3: Alarm Only0: Ramp to stop. Decelerate to stop using the deceleration timein C1-02.1: Coast to stop.2: Fast Stop. Decelerate to stop using the deceleration time inC1-09.3: Alarm only.Note: In AOLV/PM, the motor will coast to a stop(F1-03 = 1). The setting for F1-03 cannot bechanged to 0, 2, or 3.Default: 1Range: 0 to 3 –F1-04(0383) Operation Selection atDeviationPG Deviation Sel0: Ramp to Stop1: Coast to Stop2: Fast-Stop3: Alarm Only0: Ramp to stop. Decelerate to stop using the deceleration timein C1-02.1: Coast to stop.2: Fast Stop. Decelerate to stop using the deceleration time inC1-09.3: Alarm only.Default: 3Range: 0 to 3 –F1-05(0384) PG 1 Rotation Selection PG1 Rotation Sel0: Fwd = C.C.W1: Fwd = C.W.0: Pulse A leads1: Pulse B leads Default: <1>Range: 0, 1 –F1-06(0385) PG 1 Division Rate forPG Pulse Monitor PG1 Output RatioSets the division ratio for the pulse monitor used of the PGoption card installed to port CN5-C.When setting for a three-digit number “xyz”, the division ratiobecomes = [(1 + x) / yz].If only using the A pulse for one-track input, the input ratio willbe 1:1 regardless of F1-06 setting.Note: Values 033 to 101 are not available.Default: 001Min.: 001Max.: 132 –F1-08(0387) Overspeed DetectionLevel PG Overspd Level Sets the overspeed detection level as a percentage of themaximum output frequency. Default: 115%Min.: 0Max.: 120 –F1-09(0388) Overspeed DetectionDelay Time PG Overspd TimeSets the time in seconds for an overspeed situation to trigger afault (oS). Default: <1>Min.: 0.0 sMax.: 2.0 s–F1-10(0389)Excessive SpeedDeviation DetectionLevel PG Deviate Level Sets the speed deviation detection level as a percentage of themaximum output frequency. Default: 10%Min.: 0Max.: 50 –F1-11(038A)Excessive SpeedDeviation DetectionDelay Time PG Deviate Time Sets the time in seconds for a speed deviation situation to triggera fault (dEv). Default: 0.5 sMin.: 0.0Max.: 10.0 –B.6 F: Option Settings278 YASKAWA ELECTRIC TOEP C710616 41G YASKAWA AC Drive - A1000 Quick Start Guide