4. DS1 Facility Commands4200-A2-GB20-00 August 2002 4-11ExampleReport DS1 facility operational parameters for NTT1-3.REPT-OPSTAT-T1:TAMPA:NTT1-1;TAMPA 01-11-24 12:30:43M 42 COMPLD/* REPT-OPSTAT-T1:TAMPA:NTT1-1:42 */"NTT1-3:INCELLS,35500""NTT1-3:OUTCELLS,23300";Related CommandsNoneTable 4-9. REPT-OPSTAT-T1 Response ParametersParameter Explanationtid Target NE identificationyy-mm-dd Year, month, and dayhh:mm:ss Hour, minute, and secondM Message generated in response to an input commandc If provided, ctag; otherwise 0COMPLD CompletedDENY Input command is denied/* */ Enclosed are human readable comments – unspecified formaterrcde Error code (see Appendix A,Error Codes)aid_ds1 As described for command parameters (see Table 4-8, REPT-OPSTAT-T1 Command Parameters).op_ds1 DS1 operational parameter. Values are:INCELLS: Rolling count of cells received on this facility.OUTCELLS: Rolling count of cells transmitted on this facility anddiscarded for any reason.INCELLSUKN: Rolling count of cells received on this facility anddiscarded during header validation with unrecognized VPI/VCI values.OCD: Rolling count of Out of Cell Delineation events on this facility.STATUSCD: Current status of cell delineation state. Values are:– Normal: No failure condition– LOCD: Loss Of Cell Delineationvalue Value of parameter specified by op_ds1.