13. Synchronization Commands13-6 August 2002 4200-A2-GB20-00RTRV-SYNCNThe RTRV-SYNCN Command retrieves the configuration of the reference sourcefor synchronization of the NE clock.Response FormatIf, in less than 2 seconds, a normal or error response cannot be sent, the followingacknowledgment response is sent:IP cAfter the above response, a new command input may be generated.Normal Response:sid yy-mm-dd hh:mm:ssM c COMPLD/* RTRV-SYNCN:[tid]:[aid_syncn]:[ctag][:] */aid_syncn::[syncn_nblk];Error Response:sid yy-mm-dd hh:mm:ssM c DENY/* RTRV-SYNCN:[tid]:[aid_syncn]:[ctag][:] */errcde;Table 13-5. RTRV-SYNCN Command ParametersRTRV-SYNCN:[tid]:[aid_syncn]:[ctag][:];Restrictions: All parameters in this command are position-defined.[tid] Identification of the target NE. The default value is null. The NE SIDcode is the only other valid value.[aid_syncn] AID of the NE clock. The value is CLKSRCNT.[ctag] Correlation tag (6 characters maximum) that links an input commandwith associated output responses. The default is 0.