10. Fault Commands4200-A2-GB20-00 August 2002 10-11ExampleRetrieve all service-affecting critical alarms for Network Termination Unit B.RTRV-ALM-EQPT:TAMPA:NTB::CR,,SA;TAMPA 02-06-27 03:38:43M 42 COMPLD/* RTRV-ALM-EQPT:TAMPA:NTB:42::CR,SA */":NTB,EQPTS:CR,INT,SA,,,NEND,RCV,:Unknown error inmodule";Related CommandsNonecond_eqpt Equipment condition. Valid values are:EQPT: Equipment failed self-testFANALM-1: Fan alarm for fan 1FANALM-2: Fan alarm for fan 2PROGVER: Failed to load or find requested software or configurationfileRMTDLFAIL: Failed to download software or configurationSWROLLBACK: Software version rolled backserveff As described for command parameters (see Table 10-5,RTRV-ALM-EQPT Command Parameters), except that ALL is not used.[cond_descr] Description of alarm conditionTable 10-6. RTRV-ALM-EQPT Response Parameters (2 of 2)Parameter Explanation