7. Equipment Commands7-4 August 2002 4200-A2-GB20-00REPT ALM EQPTThe REPT ALM EQPT message reports current alarms from the NE.Table 7-3. REPT ALM EQPT Message Parametersalmcde atag REPT ALM EQPT aid_eqpts:ntfcde,cond_eqpt,srveff,[ocrdat],[ocrtm]: [conddescr];almcde Alarm code. Identifies the severity of the alarm. Values are:– *C: Critical alarm– **: Major alarm– *^: Minor alarm– A^: Automatic message (typically reports a cleared alarm)atag Automatic tag. Indicates the numerical sequence of reported messages.aid_eqpts Access identifier for the equipment. Each AID format can be precededwith AID=, but this is not required. Enter in the following format,replacing lower-case parameters with the values given:– LT-rack-shelf-slot: LT unit– SHELF-rack-shelf: shelf– rack: Rack Number (1)– shelf: Shelf Number (1)– slot: LT Slot Number (1)[ntfncde] Notification code. Valid values are:– CR: Critical alarm– MJ: Major alarm– MN: Minor alarm– CL: Cleared alarmcond_eqpt Equipment condition. Valid values are:– EQPT: Equipment failed self-test– FANALM-1: Fan alarm for fan 1– FANALM-2: Fan alarm for fan 2– PROGVER: Failed to load or find requested software– RMTDLFAIL: Failed to download software– SWROLLBACK: Software version rolled back[serveff] Service effect. Valid values are:– SA: Service affecting– NSA: Not service affecting[ocrdat] Date of alarm occurrence in the format mm-dd (month-day).[ocrtm] Time of alarm occurrence in the format hh-mm (hour-minute).[conddescr] Description of alarm condition (40 characters maximum).