5. ATM Commands5-14 August 2002 4200-A2-GB20-00Error Response:sid yy-mm-dd hh:mm:ssM c DENY/* RTRV-ATMPORT:[tid]:aid_atmport:[ctag]::::[pstf][sstf]*/errcde;Table 5-12. RTRV-ATMPORT Response ParametersParameter Explanationtid Target NE identificationyy-mm-dd Year, month, and dayhh:mm:ss Hour, minute, and secondM Message generated in response to an input commandc If provided, ctag; otherwise 0COMPLD CompletedDENY Input command is denied/* */ Enclosed are human readable comments – unspecified formaterrcde Error code (see Appendix A,Error Codes)aid_atmport As described for command parameters (see Table 5-11,RTRV-ATMPORT Command Parameters).state State from the Bellcore model. Values are:IS-NR. In service, normal.OOS-AU: Out of service, autonomous.OOS-MA: Out of service, management. Transient state (changes toOOS-AUMA).OOS-AUMA: Out of service, autonomous and management.sstf As described for command parameters (see Table 5-11,RTRV-ATMPORT Command Parameters).atmport_nblk SEGID: ATM segment location ID. A 16-octet field that identifies thisATM interface for OAM F5 loopbacks. When a segment F5 OAMloopback cell is received, the destination segment location in the cell iscompared to the segment location ID for the card. If the destinationlocation ID matches the location ID or is all ones, the cell is looped backto the source. If there is not a match, the cell passes through the card.The value is entered as 32 hexadecimal characters or ALLONES(default). Allowed values are restricted per ITU-T1.610 as follows: The first byte must be 01, 02, 03, FF or 6A. If the first octet is FF, then octets 2−16 must also be FF. If the first octet is 6A, then octets 2−16 must also be 6A.If no value is specified for this field, then this parameter remains thesame.