2 FlexGripper-Vacuum2.5.3. Magnetic proximity switch553HAC040633-002 Revision: -2.5.3. Magnetic proximity switchThe magnetic proximity switch is located as shown in the figure below.Position 1Use this procedure to remove the magnetic proximity switch.DANGER!Turn off all electric power and pneumatic pressure supplies to the gripper!Position 1en1012013Position 2en1012013A Magnetic proximity switchAction Note1. Loosen the small bolt.en1012015Parts: A: Small bolt2. Open the terminal box and remove thecable.See the circuit diagram for details.3. Remove the magnetic proximity switch.Continues on next page