7.7.5 Parameter 50-03: Position Actual Value (0x6064)This object provides the actual value of the position measurement device. The value is given in user-defined position units.Attribute ValueIndex 0x6064LCP parameter number 50-03Name Position actual valueObject code VarData type INTEGER32Sub-index 0x00Access Read onlyPDO mapping OptionalValue range INTEGER32Default value –Table 7.74 0x6064: Position Actual Value7.7.6 Parameters 50-30 and 50-31: Position Range Limit (0x607B)This object indicates the configured maximum and minimum position range limits. It limits the numerical range of the inputvalue. On reaching or exceeding these limits, the input value automatically wraps to the other end of the range.To disable the position range limits, set the minimum position range limit (sub-index 0xd01) and the maximum positionrange limit (sub-index 0x02) to 0 (default value). The values are given in user-defined position units.Attribute ValueIndex 0x607BName Position range limitObject code ArrayData type UNSIGNED8Sub-index 0x00Description Value of highest sub-indexAccess ConstPDO mapping NoDefault value 0x02Sub-index 0x01LCP parameter number 50-30Description Minimum position range limitAccess Read/writeData type INTEGER32PDO mapping OptionalValue range INTEGER32Default value 0Sub-index 0x02LCP parameter number 51-31Description Maximum position range limitAccess Read/writeData type INTEGER32PDO mapping OptionalValue range INTEGER32Servo Drive Parameter Descr... VLT® Integrated Servo Drive ISD® 510 System262 Danfoss A/S © 01/2017 All rights reserved. MG36D10277