9.3.2 Warnings and AlarmsCode Name Severity(Warning/error/triplock)Description LCP name0x0000 No error Error No error. –0x1000 Generic application error Error Generic application error. generic err0x2120 Ground fault Error There is current from the outputphases to ground.ground fault0x2340 Short circuit Error There is a short circuit in UDC outputfrom SAB (DC Line1 and/or DC Line2).Remove power to the SAB and repairthe short circuit.short circuit0x2391 AUX 1 overcurrent Error Current on AUX Line 1 reachedovercurrent limit.AUX1 overcurr0x2392 AUX 2 overcurrent Error Current on AUX Line 2 reachedovercurrent limit.AUX2 overcurr0x2393 AUX 1 user limit current Warning,errorCurrent on AUX Line 1 reached user-defined limit.AUX1 curr limit0x2394 AUX 2 user limit current Warning,errorCurrent on AUX Line 2 reached user-defined limit.AUX2 curr limit0x2395 AUX 1 fuse failure Error HW fuse failure.Current or voltage above limit on AUXLine 1.AUX1 fuse fail0x2396 AUX 2 fuse failure Error HW fuse failure.Current or voltage above limit on AUXLine 2.AUX2 fuse fail0x2397 DC 1 overcurrent Error Overcurrent on DC Line 1. The SABpeak current limit (approximately 200%of the rated current) is exceeded.DC1 overcurr0x2398 DC 2 overcurrent Error Overcurrent on DC Line 2. The SABpeak current limit (approximately 200%of the rated current) is exceeded.DC2 overcurr0x2399 DC overcurrent Error Overcurrent. The SAB has reached thecurrent limit and shuts down toprevent any damage to the hardware.DC overcurr0x239B Overload on output (I2T) Warning,errorThe SAB is about to cut out due to anoverload (more than 100% for toolong). The counter for electronic,thermal SAB protection triggers awarning at 90% and trips with an errorat 100%.overload0x239D DC overcurrent Warning,errorOvercurrent. The SAB has reached thecurrent limit and shuts down toprevent any damage to the hardware.DC overcurr0x3130 Mains phase loss Warning,errorMains phase loss detected. This occurswhen a phase on mains is missing, orwhen the mains is imbalanced.phase loss0x3210 DC link overvoltage Error The DC-link voltage exceeds the limitand the SAB trips.UDC overvolt0x3220 DC link undervoltage Error The DC-link voltage is below the limitand the SAB trips.UDC undervolt0x3291 UAUX high voltage Warning UAUX above warning limit. UAUX high volt0x3292 UAUX overvoltage Error UAUX above overvoltage limit. UAUX overvoltDiagnostics VLT® Integrated Servo Drive ISD® 510 System374 Danfoss A/S © 01/2017 All rights reserved. MG36D10299