ControlsContextual help of the web interface – 45•••••3.4 Controls3.4.1 Entire UPSControls are displayed for the entire UPS, and not for specific outlet options.The table in this section displays UPS status, the associated commands (on/off), and the pending action.3.4.1.1 StatusReflects the current mode of the UPS. The following is a list of potential table values that are displayed based on the UPS topology.On — Protected/Not protectedOff — Not powered/Not protected3.4.1.2 CommandsA set of commands are available and activated when one of the following buttons is pressed. A confirmation window appears.Safe OFFThis will shut off the load. Protected applications will be safely powered down.This control is available only if the status is not OFF and if there are no active commands running.Safe rebootThis will shut off and then switch ON the load. Protected applications will be safely powered down.This control is available only if the status is not OFF and if there are no active commands running.Switch ONThis will switch ON the load or turn ON the online UPS.This control is available when the status is OFF, if there are no active commands running and if the Online UPS is on bypass.3.4.1.3 Pending actionDisplays the delay before shutdown and delays before startup.