Accessing Power and Performance Data I-7Command Line (Example)C:\VBS> cscript //nologo Sensor.vbsExecution Result (Example)===========================================ID String = Front Panel TempSensor Type = TemperatureCurrent Value = 27 degrees C===========================================ID String = Baseboard Temp1Sensor Type = TemperatureCurrent Value = 50 degrees C===========================================ID String = Baseboard Temp2Sensor Type = TemperatureCurrent Value = 53 degrees C===========================================ID String = IO Riser TempSensor Type = TemperatureCurrent Value = 43 degrees C===========================================ID String = M1 DIMM 1A TempSensor Type = TemperatureCurrent Value = 37 degrees C===========================================::Inlet air temperature data is obtained from the sensor that contains the character string "Amb","Ambient", or "Front Panel" in its ID String.In the example above, the data is obtained from "Front Panel Temp" sensor, and the sensor readingis 27ºC.