Problems with lines / 599N0130943 02 Modular ICS 7.1 Installer GuidePossible problemLines are still hung after all the above solutions have beeninvestigated or tried out.SolutionFor lines that are hung for any other reason, you will have torun a Maintenance session.1. Run a Maintenance session and go to Module status.2. Disable and enable the affected Trunk Cartridge.Follow the procedures in the General troubleshootingprocedure on page 590 before proceeding.Auto-answer line rings at a telephoneThis section describes possible problems and solutions if anauto-answer line mistakenly rings at a telephone.Possible problemYou configured a loop start trunk as auto-answer but theinstalled hardware does not support disconnect supervision. Inthis case, the symptom would be accompanied by the Alarm62 code symptom.SolutionReconfigure the trunk as manual-answer.ORReplace the Trunk Cartridge with one that provides disconnectsupervision.