3-391 Before Using the Products2 Preparation3 Connection4 Setup5 Adjustment6 When in Trouble7 SupplementTitle ofsignal Alarm clear input Relatedcontrol mode P S T FSymbol A-CLR Default assignment SI8 I/F circuit SI 3-30 page• Clears the alarm condition.• This input cannot clear some alarms.• For details, refer to P.6-3 When in Trouble “Protective function”, P.2-63 “(8) Alarm Display”and P.7-25 “Display of Battery Alarm”.Title ofsignal Command pulse inhibition input Relatedcontrol mode P S T FSymbol INH Default assignment SI10 I/F circuit SI 3-30 pageCaution• Ignores the positional command pulse.• When using this feature, set Pr5.18 “Invalidation of command pulse inhibition input” to 0.This function can be assigned to only SI10. Allocation of this function to any other pin willcause an error.Title ofsignal Control mode switching input Relatedcontrol mode P S T FSymbol C-MODE Default assignment SI9 I/F circuit SI 3-30 pageCaution• Selects a control mode.This signal is required in all control modes. No setting will cause an error.Title ofsignal Electronic gear (division/multiplication) switching input 1 Relatedcontrol mode P S T FSymbol DIV1 Default assignment SI5 I/F circuit SI 3-30 pageTitle ofsignal Electronic gear (division/multiplication) switching input 2 Relatedcontrol mode P S T FSymbol DIV2 Default assignment — I/F circuit SI 3-30 page• Up to 4 numerators can be used for command dividing/multiplying by using DIV1 and DIV2. and DIV2 vs numerator/denominator of selected command dividing/multiplying process>DIV1 DIV2 Selected command dividing/multiplying processNumerator DenominatorOFF OFF Pr0.09 Pr0.10ON OFF Pr5.00 Pr0.10OFF ON Pr5.01 Pr0.10ON ON Pr5.02 Pr0.10Title ofsignal Damping control switching input 1 Relatedcontrol mode P S T FSymbol VS-SEL1 Default assignment SI3 I/F circuit SI 3-30 pageTitle ofsignal Damping control switching input 2 Relatedcontrol mode P S T FSymbol VS-SEL2 Default assignment — I/F circuit SI 3-30 pageNote• Selects applicable frequency for damping control.Combination of damping control input changeover 1 and 2 (VS-SEL1, VS-SEL2) enablesselect of max. 4 options.Also refer to P.4-21 “Pr2.13 [Damping filter switching selection]”.4. Inputs and outputs on connector X4Input Signal and Pin No. PreviousNext |