2-56OutlineTo prevent operational error e.g. unintentional parameter modification, the front panelmay be locked.Once locked, operations on the panel are limited as follows:Mode Locked panel conditionsMonitor Mode No limitation: all monitored data can be checked.Parameter Set up Mode No parameter can be changed but setting can be checked.EEPROM Write Mode Cannot be run. (No display)Auxiliary Function Mode Cannot be run except for “Release of front panel lock”. (Nodisplay)How to operate• Related parametersParameter No. Title FunctionClass No.5 35 Setup of front panel lock Locks the operation attempted from the frontpanel.Lock and unlock can be made in one of two ways.Procedure Front panel Setup support softwarePANATERMLock(1) Set Pr5.35 “Front panel lock” to 1, and writ the setting to EEPROM.(2) Turn on power to the driver.(3) The front panel is locked.Unlock(1) Execute the auxiliary functionmode, front panel lock releasefunction.(2) Turn on power to the driver.(3) The front panel is unlocked.(1) Set Pr5.35 “Front panel lock” to 0,and writ the setting to EEPROM.(2) Turn on power to the driver.(3) The front panel is unlocked.Note For details of front panel lock release, refer to P.2-81.2Preparation15. How to Use the Front PanelSetup of front panel lock