1084 CHAPTER 66: NQA C ONFIGURATION COMMANDSParametertimes: Number of constant test failures.DescriptionUse the test-failtimes command to set the number of constant test failures afterwhich the system will send the Trap information to the network managementsystem.Use the undo test-failtimes command to restore the number of constant testfailures to the default value.By default, the system sends the Trap information to the network managementsystem after one NQA test fails.n For the concept of test and probe, note the following content:■ When probing, the system sends one packet every time. While the test processis not always so.■ One test may include many probes. The test succeeds as long as there is onesuccessful probe.■ The current "probe failure times" will be reset to zero after a test is finished,that is, the "times" is only valid for a single test and can not cross two tests forconstant statistics. If the probe succeeds, this statistic value is reset to zero too.Related command: probe-failtimes.Example# Set that the system sends Trap information after 3 constant probe failures in anNQA test.system-viewSystem View: return to User View with Ctrl+Z.[SW8800] nqa-agent enable[SW8800] nqa administrator icmp[3Com-administrator-icmp] test-failtimes 3test-type Syntaxtest-type typeViewNQA test group viewParametertype: Type of test, currently it is only the icmp type.By default, the test type is icmp.DescriptionUse the test-type command to configure the test type.n The test type is required, so no undo command is provided.