1-19Use the undo dot1x timer reauth-period command to restore the default 802.1x re-authenticationinterval.By default, the 802.1x re-authentication interval is 3,600 seconds.Examples# Set the 802.1x re-authentication interval to 150 seconds. system-viewSystem View: return to User View with Ctrl+Z.[Sysname] dot1x timer reauth-period 150dot1x version-checkSyntaxdot1x version-check [ interface interface-list ]undo dot1x version-check [ interface interface-list ]ViewSystem view, Ethernet port viewParametersinterface-list: Ethernet port list, in the form of interface-list= { interface-type interface-number [ tointerface-type interface-number ] } &<1-10>, in which interface-type specifies the type of an Ethernetport and interface-number is the number of the port. The string “&<1-10>” means that up to 10 port listscan be provided.DescriptionUse the dot1x version-check command to enable 802.1x client version checking for specified Ethernetports.Use the undo dot1x version-check command to disable 802.1x client version checking for specifiedEthernet ports.By default, 802.1x client version checking is disabled on all the Ethernet ports.In system view:z If you do not provide the interface-list argument, these two commands apply to all the ports of theswitch.z If you specify the interface-list argument, these commands apply to the specified ports.In Ethernet port view, the interface-list argument is not available and the commands apply to only thecurrent Ethernet port.Examples# Configure Ethernet 1/0/1 to check the version of the 802.1x client upon receiving authenticationpackets. system-viewSystem View: return to User View with Ctrl+Z.[Sysname] interface Ethernet 1/0/1[Sysname-Ethernet1/0/1] dot1x version-check