4-4Use the undo system-guard ip detect-maxnum command to restore the maximum number ofinfected hosts that can be monitored to the default setting.By default, System Guard can monitor a maximum of 30 infected hosts.Examples# Set the maximum number of infected hosts that can be concurrently monitored to 50. system-viewSystem View: return to User View with Ctrl+Z.[Sysname] system-guard ip detect-maxnum 50system-guard ip detect-thresholdSyntaxsystem-guard ip detect-threshold ip-record-threshold record-times-threshold isolate-timeundo system-guard ip detect-thresholdViewSystem viewParametersip-record-threshold: Maximum number of IP addresses that can be learnt within a 10-second cycle, inthe range of 1 to 100.record-times-threshold: Maximum number of times an IP address must be hit before an action can betaken, in the range of 1 to 10.isolate-time: Isolation time, in the range of 3 to 100. After System Guard takes an action on ansuspected IP address, the system will wait isolate-time before it learns destination address(es) again forthat source IP address.DescriptionUse the system-guard ip detect-threshold command to set the maximum number of addresses thatthe system can learn, the maximum number of times an address can be hit and the address isolationtime.Use the undo system-guard ip detect-threshold command to set the maximum number of addressesthat the system can learn, the maximum number of times an address can be hit and the addressisolation time to the default settings.By default, ip-record-threshold, record-times-threshold and isolate-time are set to 30, 1 and 3respectively.