2-14z Falling threshold: 5z Event 1 is triggered when the change ratio is larger than the rising threshold.z Event 2 is triggered when the change ratio is less than the falling threshold.z The alarm entry is valid forever.z Entry owner: user1 system-viewSystem View: return to User View with Ctrl+Z.[Sysname] interface Ethernet 1/0/1[Sysname-Ethernet1/0/1] rmon statistics 1[Sysname-Ethernet1/0/1] quit[Sysname] rmon prialarm 2 ((.1.3.6.1.2.1.16.1.1.1.4.1)*100) test 10 changeratiorising_threshold 50 1 falling_threshold 5 2 entrytype forever owner user1# Remove the extended alarm entry numbered 2 from the extended alarm table.[Sysname] undo rmon prialarm 2rmon statisticsSyntaxrmon statistics entry-number [ owner text ]undo rmon statistics entry-numberViewEthernet port viewParametersentry-number: Statistics entry Index, in the range 1 to 65535.owner text: Specifies the owner of the entry, a string of 1 to 127 characters.DescriptionUse the rmon statistics command to add an entry to the statistics table. If you do not specify the ownertext keyword/argument combination, the owner of the entry is displayed as “null”.Use the undo rmon statistics command to remove an entry from the statistics table.The RMON statistics management function is used to take statistics of the usage of the monitored portsand errors occurred on them. The statistics includes the number of the following items:z Collisionsz Packets with CRC errorsz Undersize/Oversize packetsz Broadcast/Multicast packetsz Received packetsz Received bytes