NoteActionxx2300001077Fit and secure the R1.CP and R1.CS con-nectors to the customer plate.8Torx pan head screw: M3x12 Stainlesssteel A2-70 (2 pcs/connector)Tightening torque:• Brass coupling 1/2": 31 Nm.• Stainless steel coupling 1/2": 49Nm.• Brass coupling 3/8": 17 Nm.• Mixed metals: Use the lower tighten-ing torque value of the two metals.Always apply Molykote P1900 to stainlesssteel couplings and apply if needed forcouplings of mixed metals or brass.Connect the rest of the cable connectorsto the customer plate.CAUTIONDo not tighten the brass couplings for waterand air with excessive force.CAUTIONIf the M12 Ethernet connector is nottightened correctly, there is a risk that theconnector can loosen and the cable shieldgets disconnected, which will requireretightening with the correct torque tools.For secure connection, always tighten atthe knurled screw with correct torque andby using proper torque tool, e.g. M12 dy-namometric screwdriver SW15 (09 99 0000646 (article number at Harting TechnologyGroup)).9Tightening torque, Ethernet M12: 0.6 Nm.Re-check all cables and hoses for strainingor twisting.Reroute if necessary!xx2300001081Continues on next pageProduct manual - DressPack IRB 5710 593HAC082052-001 Revision: D© Copyright 2022-2024 ABB. All rights reserved.3 Installation3.5.1.1 Fitting the lower arm MH cable packageContinued