Note/IllustrationActionLocation of wrist strap button:ELECTROSTATIC DISCHARGE(ESD)When handling the computer outside ofthe controller, use the wrist strap buttonlocated on the side of the computer.2xx2100001295Reconnect:• A2.X9 - T4.X3• A2.X10 - T4.X1• A1.X6 - A2.X11• A1.X13 - A2.X12• A2.X13 - G1/G2.X13Concluding procedureNote/IllustrationActionRefitting the controller cover on page 121.Refit the top cover.1Restoring the hardware settings on page 145.Restore the hardware settings.2Perform the function tests to verify thatthe safety features work properly, seeFunction tests on page 110.3Restoring the hardware settingsThe controller hardware settings include information such as controller type andserial number. When the computer and logic unit has been replaced, the serialnumber must be restored before any software can be installed, or any licencescan be imported.NoteWhen replacing the computer and logic unit, both the serial number and licencesare lost. The serial number must be restored as described below. Licenceshowever, can either be restored automatically when the RobotWare system isinstalled, or manually through Manage Licences in RobotWare InstallationUtilities.Note/IllustrationActionDownload the hardware information file(hwsettings.rsf) from MyABB, or from aprevious system backup.1Continues on next pageProduct manual - OmniCore E10 1453HAC079399-001 Revision: C© Copyright 2019-2022 ABB. All rights reserved.5 Repair5.2.5 Replacing the computer and logic unitContinued