Protection classesProtection classIP20Controller cabinet, inner compartment forelectronicsIP54FlexPendantNoise emissionNoteDescriptionData< 55 dB(A) Leq below +35°CThe sound pressure level onemeter away from each surfaceof the controller.Noise emission< 60 dB(A) Leq between +35°Cand +45°CPower supplyValueMains220/230 VAC, 1 phaseVoltage for OmniCore E10100-230 VAC, 1 phase i+10%, -15%Voltage tolerance+10%, -10% i50/60 HzFrequency±3%Frequency tolerancei For IRB 1100 controller.NoteThe 2 phases (180-degree phase shift, with grounded neutral), also calledSingle-phase three-wire system in North America, can be supported by thiscontroller.Load currentThere is no integrated fuse inside the OmniCore E10 controller. Add an externalfuse (time-delay) or circuit breaker (class K) according to full load current, asmarked on the controller nameplate. The following table shows the recommendedrating for an external fuse or circuit breaker.Add an external circuit breaker (class K) according to full load current, as markedon the controller nameplate. The following table shows the recommended ratingfor an external fuse or circuit breaker.CurrentDescriptionRobot10 A100-230 VAC, 1 phaseIRB 110010 A100-230 VAC, 1 phaseIRB 120010 A220/230 VAC, 1 phaseIRB 130010 A220/230 VAC, 1 phaseIRB 910INV10 A220/230 VAC, 1 phaseIRB 920Continues on next page38 Product manual - OmniCore E103HAC079399-001 Revision: C© Copyright 2019-2022 ABB. All rights reserved.2 Controller description2.2 Technical data for OmniCore E10 controllerContinued