ESOUT - emergency stop outputDescriptionPinHigh side terminal of Emergency stop output Channel 1.ESOUT1+Low side terminal of Emergency stop output Channel 1.ESOUT1-High side terminal of Emergency stop output Channel 2.ESOUT2+Low side terminal of Emergency stop output Channel 2.ESOUT2-NoteThe ESOUT pins fulfill the IEC 61131-2 Type 0,25 Output.NoteThe device connected to the ESOUT pins shall fulfill the IEC 61131-2 Type 1Input.If the device cannot meet the requirement, a safety PLC or relay is needed. ABBSafety Relay E1T 1 s, 24DC is recommended.ESOUT1 +ESOUT1-Safety PLCor RelayRelay Output forSafety Inputof Next StageESOUT2 +ESOUT2-Safety PLCor RelayRelay Output forSafety Inputof Next StageIsola!onIsola!onK2.X15Customer provided device14131211xx2000001763NoteState 0 of Emergency stop output shall be recognized as Emergency stoptriggered.NoteThe maximum length of the cable connected to the ESOUT pins shall be 10 m.Continues on next pageProduct manual - OmniCore E10 933HAC079399-001 Revision: C© Copyright 2019-2022 ABB. All rights reserved.3 Installation and commissioning3.5.8 Descriptions for connectorsContinued