Chapter 55-12F-5-203. ADF Being ClosedNo. 1 mirror base: at point of original detectionscanning lamp: off -> onoriginal sensor: original detection operation- When the ADF is at 25 deg or lower, the external light within the width of any original is kept out of external light, thus causing the machine to assumethe absence of an original at points of external light detection (external light search operation).The ADF open/closed sensor 2 identifies the state as being "closed," and the machine starts original size detection.Here, B5, B4, A4, and A3 are eliminated from the list of possible sizes.- When the external light search is over, the machine turns on the xenon lamp for the main scanning lamp, and checks the CCD (4 points) for external light.For sub scanning direction, the machine starts to operate the original sensor.F-5-21F-5-224. ADF Fully Closed (5 deg or less)No. 1 mirror base: at point of original detectionscanning lamp: onoriginal sensor: original detection operationThe machine looks for a change in the output level of individual sensors for a period of 2 sec after the ADF open/closed sensor 1 has identified thecurrent state as being "closed." The absence of a change in the level causes the machine to assume the presence of an original at the point in question.The machine uses the combination of changes in the levels of 5 points to identify the size of the original in question.F-5-235. In a Wait State (for a press on the Start key)No.1 mirror base: at point of original detectionscanning lamp: offoriginal sensor: offF-5-24(externallight)(externallight)255