Chapter 1717-35F-17-524) When you are done, turn off and then on the main power of the machine.5) See the status of upgrading indicated on the control panel of the machine. When a message appears asking you to turn off and then on the machine, turnoff and then on the main power.You will not be able to download G3Fax twice in succession. (Once downloading is executed, the board will be reset, causing download mode to end.)Be sure never to turn off the machine while it is executing a downloading session or writing downloaded system software. Otherwise, the write operation(to the flash ROM DIMM of the G3 fax board) may fail, preventing board functions. In the event the board fails to function, be sure to replace the flashROM DIMM found on the G3 fax board.17.4.10 Uploading and Downloading Backup Data17.4.10.1 Outline0008-7845SramImg is data that is stored in the SRAM of the main controller PCB, while MeapBack is a MEAP application and its data stored on the HDD.T-17-5- If you are replacing the main controller PCB, you can transfer such data as parts counter readings by uploading the data before replacement anddownloading it after replacement.- If you are replacing the HDD or executing 'ALL' or 'APL_MEP', you can temporarily set aside MEAP applications by uploading MeapBack beforeexecution and downloading it after execution.- Only the machine uploaded can download SramImg and MeapBack.Backup data Files to select for downloading/uploadingMain controller PCB backup RAM SramImg.binMEAP application MeapBack.binfor R&D Sublog.txt