Chapter 1616-27T-16-24T-16-25T-16-26T-16-27COPIER > ADJUST > HV-PRISub-item Description LevelPRIMARY Use it to enter the current setting of the primary charging assembly.settings range: 0 to 1400 (default: 771) 1COPIER > ADJUST > HV-TRSub-item Description LevelTR-N1 Use it to adjust the output level of the 1st side of plain paper for an N/Nenvironment.adjustment range: 100 to 400 (default: 380)1TR-N2 Use it to adjust the output level of the 2nd side for an N/N environment.adjustment range: 100 to 400 (default: 310) 1PRE-TR Use it to adjust the current level of the pre-transfer charging assembly.adjustment range: -300 to 0 (default: 220) 1HVT-TR Use it to enter the transfer charging assembly high-voltage offset value for thehigh-voltage unit.adjustment range: -100 to 100 (default: 0)1H-PRE-TR Use it to enter the pre-transfer charging assembly high-voltage offset value forthe high-voltage unit.adjustment range: -100 to 100 (default: 0)1D-PRE-TR Use it to enter the pre-transfer charging assembly high-voltage offset value forthe DC controller PCB.adjustment range: -50 to 50 (default: 0)1D-HV-TR Use it to enter the transfer charging assembly high-voltage offset value for theDC controller PCB.adjustment range: -50 to 50 (default: 0)1COPIER > ADJUST > HV-SPSub-item Description LevelSP-N1 Use it to adjust the output level for the 1st side of plain paper for an N/Nenvironment.adjustment range: -500 to 100 (default: -190)1SP-N2 Use it to adjust the output level for the 2nd side of plain paper for an N/Nenvironment.adjustment range: -500 to 100 (default: -170)1HVT-SP Use it to enter the separation charging assembly high-voltage offset levelfor the high-voltage unit.adjustment range: -100 to 1001D-HV-SP Use it to enter the separation charging assembly high-voltage offset valuefor the DC controller PCB.adjustment range: -50 to 501COPIER > ADJUST > FEED-ADJSub-item Description LevelREGISTUse it to adjust the leading edge registration.adjustment range: -50 to 50 1ADJ-REFEUse it to adjust the horizontal registration for duplex mode.adjustment range: -50 to 50 1