Chapter 1515-110001 An error has occurred at time of NE controllerstart-up.The NE controller that was connected beforepower-off is not connected at power-on.- Check the connection of the cable.0002 There is an IP error while the NE controller is inoperation.The IPC may have an open circuit or the IPCcommunication cannot be recovered.E719 There is a fault in the coin vendor.After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)0001 An error has occurred at time of coin vendor start-up.The coin vendor was connected before power-off,but is not connected at power-on.- Check the connector of the cable.0002 An IPC error has occurred while the coin vendor isin operation.The IPC may have an open circuit, or the IPCcommunication cannot be removed.The pickup/delivery signal line has an open circuit.An illegal connection has been detected.0003 While a unit price is being obtained at start-up, anerror has occurred in the communication with thecoin vendor.0011 An error has occurred at card reader start-up.The card reader that was connected before power-off is not connected at power-on.0012 An IPC error has occurred while the card reader isin operation.The IPC may have an open circuit, or the IPCcommunication cannot be recovered.E730 There is a fault in the PDL software.1001 There is an initialization error. - Execute PDL resetting.- Turn off and then on the main power.100A An error has occurred that can be fatal to thesystem (e.g., initialization error).9004 There is a fault in the PAI communication with anoutside controller.- Turn off and then back on the main power.- Check the open I/F board and cable connection.- Replace the external controller open I/F board.- Replace the main controller PCB.9005 There is a fault in video connection with anexternal controller.A006 absence of PDL response: there is no PDL responsebecause of a fault in or the absence of Subbootable.- Execute PDL resetting.- Turn off and then on the main power.- Check the connection of the SURF board.- Re-install the firmware.- Replace the main controller PCB.A007 There is a mismatch in version between themachine control software and the PDL controlsoftware.- Execute PDL resetting.- Turn off and then on the main power.- Execute full formatting and install the systemsoftware.B013 The font data is corrupted. - Turn off and then on the main power.- Re-install the system software.- Execute full formatting and install the systemsoftware.E732 There is a fault in the reader communication.0001 There is a DDI-S communication error. - Check the communication between the readerunit and the main controller.- Check the power supply of the reader unit.(Check to see if initialization takes place at start-up.)- Replace the reader controller PCB, reader relayPCB, or main controller PCB.E733 There is a fault in the printer communication.0000 The attempt at communication with the printer failsat start-up.- Check the connection of the cable between theDC controller and the main controller.- Check the power supply of the printer. (Check tosee if initialization takes place at start-up.)- Replace the DC controller PCB or the maincontroller PCB.0001 There is a DDI-P communication error.E740 There is a fault in the Ethernet board.0002 The MAC address is illegal. - Replace the main controller PCB.E743 There is a fault in the DDI communication.0000 An SCI error has occurred; the reception data isfaulty; a reception time-out error has occurred; aSEQ time-out error has occurred- Disconnect and then connect the connectorbetween the reader unit and the printer unit.- Replace the cable, reader controller PCB, andmain controller PCB.E744 There is a fault in the language file/boot ROM.Code Description Remedy