Chapter 1616-110T-16-11110. HV-PRIT-16-11211. HV-TRT-16-113COPIER > ADJUST > COLORSubheading Contents LevelADJ-Y/M/C/K Adjust the color balance for users. (Y/M/C/K color)Adjustment method- When you set a larger value, the image density becomes darker.- When you set a smaller value, the image density becomes lighter. 1Adjustment range: -8 to +8[Factory setting value / Value after RAM clear: 0]OFST-Y/M/C/K Adjust the density and color balance of a bright section. (Y/M/C/K color)Adjustment method- When you set a smaller value, fogging is reduced. 1Adjustment range: -32 to +32[Factory setting value / Value after RAM clear: 0]LD-OFS-Y/M/C/K Adjust the color balance of low-density area. (Y/M/C/K color)2Adjustment range: -8 to +8[Factory setting value / Value after RAM clear: 0]Use of this mode must be avoided as much as possible when the machine has been operatingnormally.MD-OFS-Y/M/C/K Adjust the color balance of middle-density area. (Y/M/C/K color)2Adjustment range: -8 to +8[Factory setting value / Value after RAM clear: 0]Use of this mode must be avoided as much as possible when the machine has been operatingnormally.HD-OFS-Y/M/C/K Adjust the color balance of high-density area. (Y/M/C/K color)2Adjustment range: -8 to +8[Factory setting value / Value after RAM clear: 0]Use of this mode must be avoided as much as possible when the machine has been operatingnormally.COPIER > ADJUST > HV-PRISubheading Contents LevelPRIMARY Adjust the current of the primary charging assembly.1Adjustment range: 0 to 1200 (Unit: μA)[Factory setting value / Value after RAM clear: 1000]GRID Adjust the grid bias of the primary charging assembly.1Setting range: 0 to 1000 (Unit: 1V)[Factory setting value / Value after RAM clear: 464]HVRATE-3 Adjust the parameter setting ratio of the primary charging bias / laser power. (Feeding speed: 1/3speed)Adjustment methodAdjust the parameter setting ratio of the primary charging bias / laser power at the feeding speedof 1/3 speed.2Setting range: 0 to 100 (This can be set in the unit of 1.)[Factory setting value / Value after RAM clear: 100]COPIER > ADJUST > HV-TRSubheading Contents LevelPRE-TR Set a current value of the pre-transfer charging assembly. (common to Y/M/C/K)1Adjustment range: -120 to 0 (Unit: 5.0 uA)[Factory setting value / Value after RAM clear: 0]2TR-TGT1 to 8 Set an offset value for the target current value of the secondary transfer ATVC.Adjustment methodWhen the product's operation mode matches the setting of TR-ENV, TR-PPR, TR-CLR, and TR-DUP, the target current value of the secondary transfer ATVC is offset according to the settingvalue of this mode. 2Adjustment value: -10 to 10 (Unit: 2uA)[Factory setting value / Value after RAM clear: 0]Reference:6 items of 2TR-TGT, 2TR-SHR, TR-PPR, TR-ENV, TR-CLR, and TR-DUP are treated as oneset.