Chapter 1616-238IFAX-SZL Set validity/invalidity of the transmission size restriction for iFAX transmission. (only whentransmission is not performed via a server)2settings0: set restrictions; 1: do not set restrictions (only if not through server; default)In the case of setting '0',- as for upper limit value, set it in transmission data size by selecting the following:additional functions mode>System Settings>Communications Settings>E-mail/I-FaxSettings>Maximum Data Size For Setting- if sending data that the size exceeds the upper limit value, it will be #830 error.IFAX-PGD Set whether or not to permit a split transmission by page. (only when the upper limit of thetransmission data size is exceeded)This mode is used to switch "permission/non-permission" of a split transmission by page whenthe upper limit of the transmission data size is exceeded in the iFAX Simple mode.2Setting range0: Do not permit a split transmission by page.1: Permit a split transmission by page.Standard value0The split transmission by page does not assure the order of pages at the receiver. In addition, itmay be possible that any other reception job steps between the pages.When setting this mode, explain the foregoing possibility to the user and gain the consentbeforehand.MEAPSAFE Make a setting to switch to the MEAP safe mode.2Setting range0: Normal mode1: Safe modeStandard value0Safe mode works to stop the added MEAP application, and to startup the only system applicationthat was activated at initial state to start up the system safely.Set '1' to startup in safe mode in the case of system recovery processing when MEAP platformdoes not startup normally because of resource competition among MEAP applications, or theorder to register/use the service."MPSF" is indicated in the control panel screen when in safe mode.FXEX-CNT Set a temperature control hysteresis width for the external heating roller.The external heating roller of this machine has small heat capacity and the heater is frequentlyturned on and off, which causes a flickering. This mode is provided as a measure to minimize suchflickering.Evaluation methodMake sure that the temperature of the external heating roller is controlled within the setting rangeusing COPIER>DISPLAY>ANALOG>FIX-EXC.2Setting range0: Hysteresis width = ±1 deg (200 deg ±1 deg )1: Hysteresis width = ±2 deg (200 deg ±2 deg )2: Hysteresis width = ±3.5 deg (200 deg ±3.5 deg )3: Hysteresis width = ±4.5 deg (200 deg ±4.5 deg )Standard value0COPIER>OPTION>USERSubheading Contents Level