Chapter 1616-22316.6.1.4 COPIER List P (subheadings under USER) 0014-3804imagePRESS C1 P2. USERT-16-178FAN-TM1 Operation time change of fans for primary charging seriesChange the operation time of fans for primary charging series at last rotation.2Setting range: 0 to 55 (1 scale: 1 min)Standard value: 55Supplement: This service mode applies to the following three fans.- Primary exhaust fan (FM2)- Left exhaust fan (FM16)- Primary exhaust assist fan (FM18)Make sure to set the setting value to 15 min or more.This item applies to the upgraded device (DCON Ver11.03 or later, Cont Ver24.04 or later)COPIER>OPTION>USERSubheading Contents LevelCOPY-LIM Change the upper limit value of the number of copies.1Setting range1 to 9999 copiesStandard value9999SLEEP Set ON/OFF of the sleep function.1Setting range0: OFF1: ONStandard value1The sleep function is set by the timer setting in the user mode.WEB-DISP Set whether or not to display the message "web is almost empty" in the user screen.1Setting range0: Do not display the message.1: Display the message.Standard value1: Display the message.[Remarks]A) Message on the UIDisplay a warning message. (default)Whether or not to display the warning message can be set by this mode.B) Display in the service modeThe message is always displayed regardless of the value specified for this mode.COUNTER 1 Use it to set soft counter 1 for the counter status verification screen.1101: Total 1Fixed to 1, which is a factory setting value / a value after RAM clear is executed. This valuecannot be changed.COUNTER 2 Use it to set soft counter 2 for the counter status verification screen.1Setting range0 to 999Standard value108COUNTER 3 Use it to set soft counter 3 for the counter status verification screen.1Setting range0 to 999Standard value232COUNTER 4 Use it to set soft counter 4 for the counter status verification screen.1Setting range0 to 999Standard value324COPIER>OPTION>BODYSubheading Contents Level