Chapter 1616-162W-CLN-P Set the interval (number of copies) to perform automatic cleaning of the primary charging wire inthe normal environment.The setting value becomes valid after the main power switch is turned OFF/ON.2Setting range50 to 10000 (copies)Standard value2000W-CLN-T Set the interval (number of copies) to perform automatic cleaning of the charging wire of the pre-transfer charging assembly.2Setting range50 to 10000 (copies)PRI-FAN Select the primary fan drive mode.Prevent the half tone unevenness due to the soiled primary charging assembly grid.2Setting range0: Half speed in the high temperature/humidity environment1: Full speed mainly in the low temperature / low humidity environment.Standard value0The setting value becomes valid after the main power switch is turned OFF/ON.SCANSLCT Set ON/OFF of the function to calculate the scan area based on the paper size.2Setting range0: OFF (Determine the scan area by document detection.)1: ON (Determine the scan area by paper size.)Standard value0When setting as '1', if the media size is larger than the original size, productivity decreases due toa larger scanning area.DH-SW Perform Dhalf correction.2Setting range0: Do not perform Dhalf control.1: Perform Dhalf control.Standard value1The setting value becomes valid after the main power switch is turned OFF/ON.SENS-CNF Set the display of the document detection sensor.2Setting range0: AB system1: Inch systemStandard value0Due to the reader controller PCB RAM clear, the value is set as '0'. Re-define the value as '1' forinch-configuration destination machines (North America etc.,)COPIER>OPTION>BODYSubheading Contents Level