Chapter 1616-102T-16-102F-16-26T-16-103COPIER > ADJUST > ADJ-XYSubheading Contents LevelADJ-X Adjust the position of the lead edge of the optical system image (the starting position to read theimage in the sub scanning direction).Adjustment method- When the non-image width is larger than the standard value, decrease the setting value.- When the area outside of the document is copied, increase the setting value.- When you increase the setting value by 1, the starting position to read the image moves to thetrail edge by 0.1mm. (The range of reading moves to the trail edge.)- When you executed 'RAM clear' for the reader controller PCB or replaced the reader controllerPCB, enter the value indicated in the service label.11 to 211[Factory setting value: Factory adjustment value / Value after RAM clear: 20]When you changed the setting value for this item, write down the changed value in the servicelabel.ADJ-Y Adjust the CCD reading starting cell position (the starting position to read the image in the mainscanning direction).Adjustment method- When the non-image width is larger than the standard value, decrease the setting value.- When the area outside of the document is copied, increase the setting value.- When you increase the setting value by 1, the starting position to read the image moves to thefront by 0.1mm. (The range of reading moves to the front.)- When you executed 'RAM clear' for the reader controller PCB or replaced the reader controllerPCB, enter the value indicated in the service label.11 to 211[Factory setting value: Factory adjustment value / Value after RAM clear: 79]When you changed the setting value for this item, write down the changed value in the servicelabel.COPIER > ADJUST > ADJ-XYSubheading Contents LevelADJ-Y-DF Adjust the main scanning position for DF stream reading.Adjustment method- When you increase the setting value by 1, the starting position to read the image moves to thefront by 0.1mm.- When you executed 'RAM clear' for the reader controller PCB or replaced the reader controllerPCB, enter the value indicated in the service label. 11 to 211[Factory setting value: Factory adjustment value / Value after RAM clear: 109]When you changed the setting value for this item, write down the changed value in the servicelabel.ADJ-Y-FX Adjust the main scanning position for DF fixed reading.Adjustment method- When you increase the setting value by 1, the starting position to read the image moves to thefront by 0.1mm.- When you executed 'RAM clear' for the reader controller PCB or replaced the reader controllerPCB, enter the value indicated in the service label. 11 to 211[Factory setting value: Factory adjustment value / Value after RAM clear: 103]When you changed the setting value for this item, write down the changed value in the servicelabel.OriginalRead start positionDecrease the setting(so that the read startposition moves toward the rear).Increase the setting(so that the readstart position movestoward the front).