Chapter 6 Appendix — Technical informationENGLISH - 169r Error responseString Details TerminationsymbolMessage“ERR1” Undefined control command(CR)0x0d“ERR2” Out of parameter range“ERR3” Busy state or no-acceptable period“ERR4” Timeout or no-acceptable period“ERR5” Wrong data length“ERRA” Password mismatchData length 4 bytes ― 1 byte/ terminalThe / terminal of the projector conforms with RS-232C so that the projector can be connected to and controlledfrom a computer.ConnectionProjector connecting terminalsComputerD-Sub 9p (female) D-Sub 9p (male)D-Sub 9p (male)Communication cable (straight)Single projectorMultiple projectorsConnecting terminals on projector 2D-Sub 9p (female) D-Sub 9p (male)D-Sub 9p (female) D-Sub 9p (male)Connecting terminals on projector 1ComputerD-Sub 9p (male) D-Sub 9p (female)D-Sub 9p (male)Communication cableCommunication cableDIGITAL LINK compatible device ComputerD-Sub 9p (female)Projector connecting terminalsDIGITAL LINK DIGITAL LINKD-Sub 9p (male)Communication cable (straight)To connect to DIGITAL LINK compatible devicesLAN cable (straight)Notef The destination of [RS-232C] (x page 119) must be set according to the connection method.f When connecting by a DIGITAL LINK compatible device, set the [PROJECTOR SETUP] menu → [STANDBY MODE] (x page 116) settingto [NORMAL] to control the projector during standby.When [STANDBY MODE] is set to [ECO], the projector cannot be control during standby.