D.2 European StandardsFigure D.1 CE MarkThe CE mark indicates compliance with European safety and environmental regulations and is required for engaging in businessand commerce in Europe.European standards include the Machinery Directive for machine manufacturers, the Low Voltage Directive for electronicsmanufacturers and the EMC guidelines for controlling noise.This drive displays the CE mark based on the EMC guidelines and the Low Voltage Directive.• EMC Guidelines: 2004/108/EC• Low Voltage Directive: 2006/95/ECu CE Low Voltage Directive ComplianceThis drive has been tested according to IEC61800-5-1:2007, and it fully complies with the Low Voltage Directive.To comply with the Low Voltage Directive, be sure to meet the following conditions when combining this drive with otherdevices:n Area of UseDo not use drives in areas with pollution higher than severity 2 and overvoltage category 3 in accordance with IEC664.n Installing Fuses on the Input SideAlways install input fuses that comply with UL standards to prevent the drive from short circuits. Refer to FactoryRecommended Drive Branch Circuit Protection on page 243 for the appropriate fuse based on the maximum input of thedrive. Refer to Heavy Duty and Normal Duty Ratings on page 180 for information on drive input and output currents.n GroundingThe drive is designed to be used in T-N (grounded neutral point) networks. If installing the drive in other types of groundedsystems, contact your dealer or Yaskawa for instructions.u EMC Guidelines ComplianceThis drive is tested according to IEC61800-3:2004 and it complies with the EMC guidelines.n EMC Filter InstallationThe following conditions must be met to ensure continued compliance with guidelines. Refer to EMC Filters on page 239for EMC filter selection.Installation MethodVerify the following installation conditions to ensure that other devices and machinery used in combination with this drivealso comply with EMC guidelines.1. Install an EMC noise filter to the input side specified by Yaskawa for compliance with European standards.2. Place the drive and EMC noise filter in the same enclosure.3. Use braided shield cable for the drive and motor wiring or run the wiring through a metal conduit.4. Keep wiring as short as possible. Ground the shield on both the drive side and the motor side.D.2 European Standards236 YASKAWA ELECTRIC SIEP C710606 31B YASKAWA AC Drive – J1000 Technical Manualhttp://nicontrols.com